| Sign In | Join Free | My bjjsgy.com | 
 | 
Brand Name : kacise
Model Number : KBU601
Certification : CE,FDA
Place of Origin : CHINA
MOQ : 0-100
Price : $0-$2000
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 100
Delivery Time : 10-15 days
Packaging Details : Common package or custom package
host:Supply Voltage : AC220V or DC24V (choose one of the two)
host:Power Consumption : <2W
host:Display : LCD Chinese display/TFT color LCD (customized version)
host:Measuring range : 0~100NTU
host:Resolution : 0.01NTU、0.1NTU、1NTU、0.01mg/L
host:Precision : 2-3% calibration accuracy
host:Operating Temperature : Transmitter -10~65℃
host:Material : PVC
host:Protection Level : I65/IP67(customized version)
host:Signal Output : 485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA Communication (function option)
host:Installation Method : Wall mount
sensor:Supply Voltage : DC5V
sensor:Protection Level : ip68
sensor:Temperature : 0-60℃
sensor:Material : 304 stainless steel (input type), PVC (circulation type)
sensor:Cable Length : Standard 10 meters (extendable)
sensor:Operating Temperature : 0-60℃
sensor:Storage Temperature : -10-60℃
sensor:Installation Method : Bracket drop-in installation / flow-through wall-mounted installation
KLT500 online low turbidity meter turbidity sensor water treatment
Production Introduction
 The turbidity meter KXTX00 series is used to measure the turbidity of water during the treatment of municipal sewage, industrial wastewater, and industrial slurry.
 An online measuring instrument designed for the concentration of suspended solids. The principle that the transmittance of light is proportional to the turbidity of the sewage on the side is used. It can be applied to detect the change of turbidity in the biochemical treatment process and provide continuous and accurate measurement results.
 Turbidity is the scattering phenomenon caused by colloidal particles suspended in water. The muddy water is mainly mud,
 Increased turbidity caused by organic matter, microorganisms and other substances indicates that the water body is polluted by colloidal substances.
  
 Measuring principle
  
 Features:
 1. The use of multi-beam mutual compensation technology can eliminate measurement errors caused by light window sticking, as well as temperature changes and components
 Parts aging and other effects
 2. LCD display, Chinese menu operation, stable performance, strong reliability, convenient operation for workers
 3. The throw-in sensor is easy to install, has high accuracy, good repeatability and strong anti-interference ability
 4. Support 485 communication 4-20mA analog output/support HART protocol/NB.GPRS.LORA communication (function option)
 5. Complete product series, with corresponding sensors for different concentration ranges, and wide measurement range.
 The sensors of the turbidity meter are mainly divided into three categories according to the different measuring ranges
 1. KLT500 The flow-through sensor is suitable for low-range, high-precision turbidity value measurement (less than 100NTU). The photosensitive components are embedded in the flow cup, completely isolated from the external light source, and the light source interference is minimized to obtain higher Resolution and more stable signal value ensure the accuracy and stability of the data.
 
| PN | Range | Resolution | Precision | 
| KLT500 | 0.1-100NTU | 0.01NTU | Accuracy 2% calibration | 
 
 It can also be used to measure the concentration of sludge, support different units, different ranges of customization.
 
  
 Turbidity meter size structure diagram
 
 Turbidity meter technical parameters
  
| Class | Performance | parameter | 
| Host | Supply Voltage | AC220V or DC24V (choose one of the two) | 
| Power Consumption | <2W | |
| Display | LCD Chinese display/TFT color LCD (customized version) | |
| Measuring range | 0~100NTU,0~500NTU,0~5000NTU | |
| Resolution | 0.01NTU,0.1NTU,1NTU,0.01mg/L | |
| Precision | 2-3% calibration accuracy | |
| Operating Temperature | Transmitter -10~65℃ | |
| Material | PVC | |
| Protection Level | I65/IP67(customized version) | |
| Signal Output | 485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA Communication (function option) | |
| Installation Method | Wall mount | |
| Sensor | Supply Voltage | DC5V | 
| Protection Level | ip68 | |
| Temperature | 0-60℃ | |
| Sensor Material | 304 stainless steel (input type), PVC (circulation type) | |
| Cable Length | Standard 10 meters (extendable) | |
| Operating Temperature | 0-60℃ | |
| Storage Temperature | -10-60℃ | |
| Installation Method | Bracket drop-in installation / flow-through wall-mounted installation | 
 
 Ordering Information Selection Table
  
| Ordering Information Selection Table | ||
| KXTX00 | PH/ORP analyzer | |
| Power supply | DC24V | |
| AC220V | ||
| Cable length | 5m | |
| 10m | ||
| 15m | ||
| 20m | ||
| Temperature compensation | Sensor without temperature compensation | |
| Sensor with temperature compensation | ||
| Signal output | Only 4-20mA | |
| Only 485 | ||
| Also with 4-20mA , 485 signal output | ||
| Special custom signal | ||
| KLT500-DC24V--5m-Sensor without temperature compensation-Only 485 | Low Turbidity host, with DC 24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication. | |
 
 Contact us
 Website: www.kacise.com
 Phone: +86-17719566736
 Email: sales@kacise.com
 Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
 
 Abbreviations table
 NTU
 The unit of turbidity is "degree", which is equivalent to the degree of turbidity produced by 1L water containing 1mg SiO2 (or white clay, diatomite), which is 1 degree, or Jackson.Turbidity unit is JTU, 1JTU=1mg/L white clay suspension.
 The turbidity shown by modern instruments is the unit of scattering turbidity NTU, also known as TU.1NTU= 1JTU.
 Recently, it is considered internationally that the standard of turbidity prepared with ullotropin-hydrazine sulfate has good reproducibility and is chosen as the uniform standard of FTU.1FTU=1JTU.
|   | 
| KLT500 100NTU Online Turbidity Controller Meter With Sensor Images | 
 Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
                                                                                    
                        
                        
                        
                                                            Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
                                                    
                        
                     Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
                                                                                    
                        
                        
                        
                                                            Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
                                                    
                        
                     Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
                                                                                    
                        
                        
                        
                                                            Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
                                                    
                        
                     Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
                                                                                    
                        
                        
                        
                                                            Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
                                                    
                        
                     NH4-N Ammonia Nitrogen Water Quality Sensor KWS-200 PH Range 4-10
                                                                                    
                        
                        
                        
                                                            NH4-N Ammonia Nitrogen Water Quality Sensor KWS-200 PH Range 4-10
                                                    
                        
                     90° Scattered Light Aquaculture Industry Water Turbidity Sensor 0 - 1000NTU
                                                                                    
                        
                        
                        
                                                            90° Scattered Light Aquaculture Industry Water Turbidity Sensor 0 - 1000NTU
                                                    
                        
                     Radial Installation Manometer Pressure Gauge Pressure Monitoring Storage
                                                                                    
                        
                        
                        
                                                            Radial Installation Manometer Pressure Gauge Pressure Monitoring Storage
                                                    
                        
                     Electromagnetic flowmeter for measuring liquid flow 0.6-4.0MPa pressure with
                                                                                    
                        
                        
                        
                                                            Electromagnetic flowmeter for measuring liquid flow 0.6-4.0MPa pressure with
                                                    
                        
                     Support MODBUS and RS-485 output digital oil in water sensors support MODBUS and
                                                                                    
                        
                        
                        
                                                            Support MODBUS and RS-485 output digital oil in water sensors support MODBUS and
                                                    
                        
                     Dissolved Oxygen Sensor Water Quality Sensor IP68 Grade For Shrimp Farm
                                                                                    
                        
                        
                        
                                                            Dissolved Oxygen Sensor Water Quality Sensor IP68 Grade For Shrimp Farm